Disintegration testing is an important in-procedure check in oral strong dosage (OSD) formulations because it ensures that the tablet or capsule will stop working and release the active pharmaceutical ingredient (API) in a very timely fashion.
Our lab uses almost exclusively Distek instruments as They may be most popular through the laboratory analysts due to their trustworthiness and simplicity of use."
Basket or Paddle Assembly: It's really a mesh basket or paddle assembly that retains the individual dosage type. The basket assembly is generally employed for tablets, when the paddle assembly is utilized for capsules.
Elevate the basket from the medium and observe the tablets. The tablets or capsules go the test if all of these have disintegrated.
Period resolved and waveform displays make it possible for much more dependable and conclusive selections for being made based on calculated PD
Should the consumer has an acceptable irradiance calibration source lamp, a field re-calibration can be effortlessly performed utilizing the integrated SpectraWiz software program.
Our community of laboratories supports you with testing plans that produce a complete variety of certification and validation services to meet your special testing desires.
PROCEDURE:- Area just one dosage unit in Every website single of your 6 tubes of your basket and when specified insert a disc. Work the apparatus working with h2o given that the immersion fluid unless A further liquid is specified and retain its temperature at 35–39 °C. At the end of the required time elevate the basket within the fluid and notice the dosage models, all the dosage units have disintegrated entirely.
Rapidly delivery: most process may be calibrated and delivered within one week immediately after receipt of order. Certification Paperwork offered
Acceptance criteria – time variation should not be more than ± 20 check here seconds concerning the Instrument timer and calibrated